Construction of the JCHYPAR, a steel fiber reinforced concrete membrane at the oceanographic park in Valencia

  • Domingo Cabo, A.; Lázaro, C.; Serna Ros,
Keywords: 0

Abstract


The following document describes the construction of a thin shell structure using steel fiber reinforced concrete (SFRC). The roof called JCHYPAR is a groined vault composed of four hyperbolic paraboloids. Shell thickness equals 6 cm and the distance between opposite supports is around 40 m. This paper will describe the whole construction process of the aforementioned structure. The following items will be analysed: previous characterization tests, shoring process, rebar placement, shotcrete process, curing process and strinking, test program and test results, and final controls and tests.
Published
2003-01-03
How to Cite
, D. C. A. L. C. S. R. (2003). Construction of the JCHYPAR, a steel fiber reinforced concrete membrane at the oceanographic park in Valencia. Hormigón Y Acero, 54(228). Retrieved from http://37.35.109.41/ojs/index.php/ache/article/view/255