Underground parking design, 306 m long, without expansion joints

  • González Serrano, A.

Abstract


This paper explains an underground parking construction, built in Palma de Mallorca, 306 m long with no expansion joints.
Published
1991-01-01
How to Cite
, G. S. A. (1991). Underground parking design, 306 m long, without expansion joints. Hormigón Y Acero, 42(178). Retrieved from http://37.35.109.41/index.php/ache/article/view/734