Pathology in structures built with precast concrete members

  • Miguel Ángel Liébana Ramos
  • Ramón Álvarez Cabal
Keywords: Precast structures, Pathology, Tolerances, Connections

Abstract


Some of the most common problems in precast concrete structures are shown in this work, through examples and real situations. These problems are associated with an underestimation of the manufacturing and assembly tolerances during the design phase, as well as, with a lack of bracing or anchoring mechanisms to ensure its stability against horizontal actions. Additionally, the requirements of current standards and quality procedures that apply to this type of elements have been examined, which in our opinion are not being enough effective.

Published
2019-04-11
How to Cite
Liébana Ramos, M., & Álvarez Cabal, R. (2019). Pathology in structures built with precast concrete members. Hormigón Y Acero, 70(287), 31-46. Retrieved from http://37.35.109.41/index.php/ache/article/view/2039